alcon sa60at a constantfenugreek dosage for male breast enlargement
[352]: data by Dr. Dale Pilkinton, Nashville, TN, USA [26]: data by K.Ichikawa, MD, Aichi, Japan ZEISS AT LISA tri839 MP A=118.3 a0= -1.477 a1=0.058 a2=0.262 pACD=5.48 sf=1.72 A=118.9 A=119.0 237 [297],[404] A private practice in Marshalltown, Iowa, USA. Alcon, a Novartis Division. [360]: data by Dr. Claudio Carbonara, Roma, Italy [160]: data by Dr.R.Lehmann, Mnchengladbach, Germany [397]: data by Prof. Dr. Schnherr, Linz, Austria [11]: data by Dr.B.Hrster and Dr.Thamaz, Erkelenz, Germany Polytech Polylens A60 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35] [352]: data by Dr. Dale Pilkinton, Nashville, TN, USA The lens has a biconvex optic with supporting haptics. Eyecryl ACTV DIYHS600ROH (*****) A=118.0 a0=0.56 a1=0.40 a2=0.10 pACD=4.67 sf=0.93 A=117.6 A=117.8 57 [349] ISPAN Sulfur Hexafluoride SF6 - For use with CONSTELLATION Vision System, KELMAN MULTIFLEX III PMMA Single-Piece Anterior Chamber Lenses, (carbachol intraocular solution, USP) 0.01%, MONOFLEX PMMA EXPAND Single-Piece Series IOLs, OPTI-FREE Express Multi-Purpose Disinfecting Solution, OPTI-FREE PureMoist Multi-Purpose Disinfecting Solution, OPTI-FREE RepleniSH Multi-Purpose Disinfecting Solution, OPTI-FREE SupraClens Daily Protein Remover, SYSTANE Lubricant Eye Drops - Preservative-Free Vials (Unit Dose), SYSTANE NIGHTTIME Lubricant Eye Ointment, SYSTANE ULTRA Lubricant Eye Drops - Preservative-Free Vials (Unit Dose), Patient Information for MODELS SA6AT6, SA6AT7, SA6AT8, SA6AT9, SN6AT6, SN6AT7, SN6AT8, SN6AT9, Professional Fitting and Information Guide. [156]: data by Francis Reid, MD, Oak Ridge, TN, USA Rayner C-flex Asph 970 C A=118.0 a0=1.19 a1=0.40 a2=0.10 pACD=5.38 sf=1.63 A=118.8 A=119.2 72 [258],[300],]92] [227]: data by PD Dr.J.Weindler, Esslingen, Germany [59]: data by E.Suarez, MD, Venezuela [7]: based on data by G.Gerten, MD, Cologne, Germany [117]: data by Dr.M.Theophil, Brandenburg, Germany [307]: data by Prof.Dr.P.Rieck, Berlin, Germany [35]: data by F.Kremer, MD, Troisdorf, Germany [402]: data by Dr. D. Breyer, Dsseldorf, Germany [131]: data by Dr.M.Rau, Furth i.W., Germany Alcon MA60MA (-diopters) A=118.9 a0= -4.22 a1=0.40 a2=0.10 pACD= -5.52 sf= -7.08 A=103.6 A=119.1 39 [143],[18],[389] [65]: data by Dr.M.V.Partyngl, Wil, Switzerland [104]: data by Prof.Dr.V.Seiberth, Germany Aaren Scientific EC-3 PAL A=117.7 a0=1.10 a1=0.40 a2=0.10 pACD=5.28 sf=1.46 A=118.4 A=118.4 47 [365] [361]: data by Dr. Thomas Hamacher, Starnberg, Germany Alcon Panoptix TFNT00 A=119.1 a0=1.39 a1=0.40 a2=0.10 pACD=5.63 sf=1.83 A=119.1 A=119.3 26 [395] [367]: data by Dr. Ralf Schmitt, Saarbrcken, Germany [27]: data by Dr.W.Lange, Prien, Germany [280]: data by John Chang MD, Hongkong ZEISS Acri.Lens 11C A=118.0 a0=1.21 a1=0.40 a2=0.10 pACD=5.46 sf=1.72 A=118.9 A=118.9 22 [16] The AcrySof IOL (model SA60AT) is an ultraviolet-absorbing acrylic foldable single-piece lens. Hoya iMics1 NY-60 (Japan) A=118.4 a0=1.29 a1=0.40 a2=0.10 pACD=5.46 sf=1.66 A=118.7 A=118.9 45 [41] [217]: data by Mr.S.Beatty, Waterford, Ireland [126]: data by S.Suh MD, Westerville, OH, USA [134]: data by Dr.Chr.Chassain, Montpellier, France INDICATION: The ClareonAspheric Hydrophobic Acrylic IOLs include the Clareon Aspheric and Clareon Aspheric Toric IOLs and are indicated for primary implantation in the capsular bag in the posterior chamber of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. 2020 - [136]: data by Dr.J.Blazek, Pardubice, Czech Republic [226]: data by Dr.T.Neuhann, Mnchen, Germany Ophtec PC 550 MonomaX A=118.0 a0=1.22 a1=0.40 a2=0.10 pACD=5.38 sf=1.63 A=118.7 A=119.0 103 [268],[274] [219]: data by Dr.Hans Klett, Herne, Germany [89]: data by Dr.T.Grasbon, Ingolstadt, Germany [274]: data by Dres.Bascaran and Dr.Oteyza, Oviedo, Spain [135]: data by B.Shingleton, MD, Boston, MA, USA Oculentis LS-312-1Y discontinued A=118.0 a0= -2.017 a1=0.066 a2=0.271 pACD=5.12 sf=1.35 A=118.3 A=118.4 291 [117],[170],[118],[86],[259] [10]: data by R.Walter-Fincke, MD, and W.Bachmann, MD, Aschaffenburg, Germany [318]: data by Dr. P. O'Brian, Dublin, Ireland Accessibility [25]: data by Dr.U.Reinking, Salzkotten, Germany [395]: data by Dr. M. Czubak, Warszawa, Poland [389]: data by Dr. C. Dulanto, Inst. Curamed SA60CZ A=118.8 a0=1.07 a1=0.40 a2=0.10 pACD=5.25 sf=1.47 A=118.5 A=118.8 151 [25] [79]: data by Dr.F.Goes, Antwerp, Belgium Oculentis L-302-1 A=118.0 a0= 1.833 a1=0.138 a2=0.096 pACD=5.11 sf=1.35 A=118.3 A=118.5 530 [117],[106],[141],[118] [379]: data by Dr .PARK Young Jeung, Daegu, South Korea Morcher TYPE 92S A=119.7 a0=1.40 a1=0.40 a2=0.10 pACD=5.60 sf=1.84 A=119.1 A=119.6 71 ]362] The biconvex optic and supporting haptics consist of a high refractive index soft acrylic material. Epub 2015 May 7. [321]: data by Dr.Hiroyuki Arai, Yokohama, Japan [153]: data by Dr.Bouchout, France Epub 2008 Apr 19. Alcon SA60AT (Japan) A=118.4 a0= -1.627 a1=0.305 a2=0.248 pACD=5.64 sf=1.83 A=118.9 A=119.2 501 [41] [40]: data by Dr.Jeffrey Sher, Hamilton, Ontario, Canada [349]: data by Dr.Dhaval S. Modi, Ahmedabad, India [271]: data by Dr.G.Sauder, Stuttgart, Germany [298]: data by Dr. L. Bauer, Bremen Spain [283]: data by Dr. K.-C.Heider, Sangerhausen, Germany Alcon ReSTOR SV25T0 (India) A=119.1 a0=1.63 a1=0.40 a2=0.10 pACD=5.84 sf=2.05 A=119.3 A=119.6 16 [314] [220]: data by Dr.Georg Leuschner, Garbsen, Germany Ophtec PC430 A=118.0 a0=0.86 a1=0.40 a2=0.10 pACD=5.08 sf=1.32 A=118.2 A=118.5 51 [11] Below are lens constants for popular IOLs to be used with the Hill-RBF calculator. Would you like email updates of new search results? If so, do not buy . To report the clinical performance characteristics of single-piece acrylic Alcon SA30AL and SA60AT intraocular lenses (IOLs). HumanOptics Aspira-aQA A=118.7 a0=1.35 a1=0.40 a2=0.10 pACD=5.53 sf=1.77 A=118.9 A=119.3 113 [398] The Alcon Monofocal Toric IOL aspheric design delivers a broad refractive landing zone, giving you predictable distance at 20/20 and consistent functional intermediate (20/32 at 66cm) visual acuity. As new IOLs are introduced, this listing will be updated. [236]: data by Dr.H.v.Wyk, Johannesburg, South Africa [50]: data by Dr.L.Henke, Gummersbach, Germany Tekia Tek-Lens Mod.614 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35] Staar AQ 2003V A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.73 sf=1.96 A=119.2 A=119.6 65 [54] AMO SI40 NB A=118.0 a0= -0.199 a1=0.276 a2=0.169 pACD=5.19 sf=1.42 A=118.4 A=118.6 1172 [2],[17],[18] [38]: data by Dr.Michaela Mees, Sulzbach, Germany PMC [16]: data by J.W.Klett, MD, Dortmund [347]: data by Dr. Ugur Unsal, Izmir, Turkey [127]: data by H.Geggle MD,Seattle, WA, USA [355]: data by Dres. We aspire to lead the world in innovating life-changing vision and eye care products because when people see brilliantly, they live brilliantly 2021 Corporate Responsibility Report Learn more Sight Innovation [364]: data by 1stQ, Mannheim, Germany Subgroups of cases were studied prospectively to evaluate 3 factors: same-day incision competence after implantation (postoperative intraoperative pressure [IOP], 107 cases); 2- to 5-week A-constant validation (200 cases); 1-day, 2-week, and 1- and 5-month descriptions of optic centration with respect to pupil and capsule anatomy (79 cases); and a 1-day versus 9-month photographic comparison of IOL centration (70 cases). Setting: Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China. ALCAINE (proparacaine hydrochloride ophthalmic solution, USP) 0.5% Product Information Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL MODEL MTA2UO-7UO Product Information BETADINE 5% Ophthalmic Prep Solution (povidone-iodine ophthalmic solution) BETADINE is a registered trademark of The Purdue Frederick Company. [378]: data by Dr. PARK Young Soon, Seoul, South Korea [235]: data by Th.Hofmann, Binningen, Switzerland [70]: data by HumanOptics AG, Germany Product number SA60AT IOLS AcrySof IQ IOL 6,0 AcrySof Multipiece 6,0 AcrySof Multipiece EXpand -1,0 AcrySof single piece 31,0 Capsular Tension Ring, ca 11mm Capsular Tension Ring, ca 12mm MA60AC MONARCH III (C) CARTRIDGES MODIFIED MONARCH III (D) CARTRIDGES SGL USE MONARCH III IOL DELIVERY SYSTHANDPIECE PMMA Single piece IOL 10,0 [24]: data by Dr.R.Kll, Landshut, Germany J.Brndle MD(Fssen, Germany), J Cataract Refract Surg. Hanita SEELENS A=118.6 a0=1.29 a1=0.40 a2=0.10 pACD=5.51 sf=1.73 A=118.9 A=119.2 51 [136] Lane S, Collins S, Das KK, Maass S, Thatthamla I, Schatz H, Van Noy S, Jain R. Evaluation of intraocular lens mechanical stability. [251]: data by Dr.T.Hanemoto, Mito, Japan . Polytech Polylens AS62 A=118.2 a0= -1.527 a1=0.152 a2=0.237 pACD=5.04 sf=1.28 A=118.2 A=118.4 342 [94],[238],[317] Europe / Middle East / Africa Gen. Innov. Alcon Toric SN6AT(3-5) (Japan)A=119.0 a0= 1.78 a1=0.40 a2=0.10 pACD=5.91 sf=2.08 A=119.3 A=119.6 77 [41] For monofocal-like distance, excellent intermediate vision and functional near, try the Clareon Vivity Extended Vision IOL.14 [110]: data by Dr.H.Wenkel, Coburg, Germany K.Lucke MD(Bremen, Germany), [309]: data by Dr.F.DeWilde, Sint Martens Latem, Belgium Oculentis LS-313-1Y discontinued A=118.0 a0= 1.10 a1=0.40 a2=0.10 pACD=5.26 sf=1.50 A=118.5 A=118.8 20 [107] The lens consists of a high refractive index soft acrylic material capable of being folded prior to insertion. The SRK T formula is a third generation formula, described in 1990 by John Retzlaff, Kraff and Sanders [6]. [283]: data by Dr. K.-C.Heider, Sangerhausen, Germany [39]: data by Ronald R.Holweger, MD, Hays, KS, USA [168]: data by Dr.C.Wirbelauer, Berlin, Germany [278]: data by Jason Jacobs, MD, Denver, CO, USA [287]: data by Dr. Alexander Tunas, Hamburg, Germany [288]: data by Aurolab, India Eyecryl ACTV +3DIHFY600 A=118.5 a0=1.24 a1=0.40 a2=0.10 pACD=5.42 sf=1.63 A=118.7 A=118.9 55 [349] [258]: data by Dr. Mark Fajgenbaum and Mr.C.Liu, Sussex, UK [57]: data by E.Viteri, MD, Ecuador [67]: data by Dr.B.Harrisburg, Sidney, Australia We partner with industry leaders in both technology and healthcare worlds to offer a quick guide that will help to find the most needed solutions for your patient needs. H.Mller-Bergh MD(Itzehoe, Germany), [142]: data by Dr.J.Bauer, Mainz, Germany [341]: data by Fredrick Lang MD, Cecanot, Dominican Republic For details click here. [120]: data by Dr.L.Tschernjakov, Berlin, Germany The SA30AL and SA60AT IOLs both have a manufacturer-identified A-constant of 118.4. [211]: data by Dr.R.Braig, Holzkirchen, Germany Depth of focus after implantation of spherical or aspheric intraocular lenses in hyperopic and emmetropic patients. Domilens Siflex8 discontinued A=118.2 a0=1.04 a1=0.40 a2=0.10 pACD=5.27 sf=1.47 A=118.3 A=118.3 34 [18] Rayner 755 U A=118.0 a0=1.60 a1=0.21 a2=0.11 pACD=5.42 sf=1.67 A=118.8 A=119.0 98 [1] [375]: data by Dr. J. Juranek, Mhldorf am Inn, Deutschland Careers. Jan 2002 Dr.Schmidt MC6125AS A=118.4 a0=0.885 a1=0.312 a2=0.125 pACD=5.36 sf=1.60 A=118.7 A=119.1 204 [70],[122] [71]: data by Dr.S.Schmickler, Ahaus, Germany M.Prskavec and M.Wirtitsch, Villach, Austria [348]: data by Dr.Budo, Belgium; Dr.Krantz-Kret, The Netherlands Physiol FineVision A=118.8 a0=1.30 a1=0.40 a2=0.10 pACD=5.55 sf=1.82 A=119.1 A=119.4 198 [330] [21]: data by A.Koletzko,MD, Moers, Germany [323]: data by Dr. Katrin Hermes, Oranienburg, Germany 2004 Jun;88(6):746-9. doi: 10.1136/bjo.2003.037663. ZEISS CT SPHERIS 204 (Acri.Lyc 44S) A=118.0 a0=0.93 a1=0.40 a2=0.10 pACD=5.16 sf=1.40 A=118.3 A=118.5 177 [16],[18],[207],[230],[404] [317]: data by Dr.K.Seftel, Halberstadt, Germany Moss Vision Optiflex MOHF-D012 A=118.5 a0=0.95 a1=0.40 a2=0.10 pACD=5.16 sf=1.43 A=118.4 A=118.6 49 [369] Subgroup studies confirmed good performance in the following parameters: There were no cases of incision incompetence evidenced by an abnormally low postoperative IOP. [156]: data by Francis Reid, MD, Oak Ridge, TN, USA If the item is subject to FDA regulation, seller must verify your status as an authorized purchaser of this item before shipping of the item. [403]: data by Prof. Dr. Rozsival, Kralove, Czech Republic [293]: data by Tomasz Trzos, Grlitz, Germany [41]: data by C.Suto, MD, Tokyo, Japan [222]: data by Dr.H.Lgel, Sulzbach, Germany Zeiss CT LUCIA 201P/PY A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.67 sf=1.93 A=119.3 A=119.9 48 [316] {148]: data by Dr.H.Schneider, Wismar, Germany Alcon, a Novartis Division The AcrySof Aspheric IOL (model SA60WF) is an ultraviolet-absorbing acrylic foldable single-piece IOL. 2015 Jun;253(6):973-7. doi: 10.1007/s00417-015-3029-8. Federal government websites often end in .gov or .mil. Pedrell Pedrola, Barcelona, Spain [348]: data by Dr.Budo, Belgium; Dr.Krantz-Kret, The Netherlands . [139]: data by Dr.C.Deman, Koksijde, Belgium The lens has a biconvex optic with supporting haptics. Ophthalmologe 2002; 99:580-583 Moss Vision Optiflex MO/F-022 A=118.5 a0=1.37 a1=0.40 a2=0.10 pACD=5.61 sf=1.85 A=119.1 A=119.5 49 [369] [98]: data by A.Rivett, Adelaide, Australia [236]: data by Dr.H.v.Wyk, Johannesburg, South Africa [203]: data by Dr.K-B.Seemann, Delmenhorst, Germany